Trouble shows up early in the season
April is when cooling starts asking this heat pump to work, and November is when heat takes over. A part that got weak sitting idle usually fails in those first weeks, not in the middle of the season.
Takes about a minute. No obligation.
April is when cooling starts asking this heat pump to work, and November is when heat takes over. A part that got weak sitting idle usually fails in those first weeks, not in the middle of the season.
If your heat pump just started acting up, the timing is probably not a coincidence. Whoever looks at it should check for a problem that was building before the season started, not just treat the symptom in front of them.

NOAA nClimDiv, 1991–2020 normals
A heat pump that's not working doesn't always sit dead. It can run and still not heat or cool the house.
If yours is running but the air feels off, the problem is usually weak airflow or a bad part, not the whole system failing.



Half the homes in Clarke County were built in 1987 or later, so plenty of heat pumps here still have a lot of working life in them. If yours came with a newer house, that's worth knowing before anyone talks about replacing it. A system acting up isn't necessarily near the end, it usually just has one part that failed. Finding that part and fixing it is the job, not writing off the whole unit.
A heat pump that came with a newer house isn't a likely candidate for a full system swap. It's a candidate for a diagnosis. Get the part that failed found and fixed.
Find a contractor
A heat pump runs both sides of the job, so it has parts a furnace never needs. The reversing valve is the one that's unique to it, and when it sticks, the system blows cold when it should heat or won't switch over at all. The contactor wears from switching on and off so many times a year, and when its contacts pit and burn, the outdoor unit stops answering the thermostat. Capacitors dry out with age and heat and no longer give the compressor or fan motor the jolt they need to start. Low refrigerant charge almost always means a leak somewhere in the line set or coil, not the system just running low on its own. Outdoor coils get coated with dirt and cut, which chokes airflow and makes the whole system work harder than it should. The defrost board and sensor earn their keep in the cold months, and when one fails, ice builds up on the outdoor coil and never clears. None of this is about one season being harder than another. It's wear that shows up whenever a part's time is up.
A heat pump low on charge or losing airflow across the outdoor coil will keep trying to hit the setpoint by running longer. That extra runtime strains the compressor, the one part that costs the most to replace. The symptom you notice, weak heating or cooling, is easy to live with for a few days. The part damage underneath is not.
A defrost board that fails lets frost build on the outdoor coil instead of clearing it on schedule. Left alone, that ice blocks airflow completely and the system stops delivering heat right when it's needed most. A contactor with burned contacts can fail the same way, going from intermittent to dead with no warning in between.
Before anyone comes out, there are a few things worth looking at on your own. Check the thermostat first. Make sure it's set to heat or cool as intended and that the setpoint is actually past room temperature, since a setting bumped by accident looks exactly like a dead system. Go to the air handler and pull the filter. If it's packed with dust, that alone can choke airflow enough to cause weak heating, weak cooling, or ice on the outdoor unit. Walk outside and look at the outdoor unit. If the coil is covered in leaves, grass clippings, or ice, that's worth noting, but don't chip at ice or hose off a running unit yourself. Check the breaker panel too. A tripped breaker to either the indoor or outdoor unit will shut the whole system down and is safe for you to reset once. If it trips again, stop and let a tech find out why.
A heat pump failing doesn't mean the whole system is done. Most of the time it means one part gave out, and the rest of the system is fine. The question worth asking is whether the failure is contained or whether it already damaged something else. A bad capacitor that gets replaced quickly usually doesn't take the compressor with it. A bad capacitor ignored for months might. Age matters less than people think. A heat pump that's been maintained and just lost a contactor or a capacitor is worth fixing almost every time. One that's been run hard with a slow leak or restricted airflow for years, so the compressor's been straining the whole time, is a different conversation. The part that failed tells you what broke. What it was doing before it failed tells you what else to check.